中文|EN
Sales Hotline:024-253 671 22
After-sales Hotline:024-893 681 33
  • Index
  • Walk Into ZiWei
    • Company Introduction
    • Qualifications and Honours
    • Corporate Culture
    • Development History
    • Exhibition
  • News Center
    • Company News
    • Industry News
  • Product Center
    • Aeronautics & Astronautics/Military industry Aeronautics & Astronautics/Military industry
      Aeronautical test stand Astronautical test stand Weapon test platform More...
    • Filter Filter
      Air conditioner filter Air filter Automotive oil and gas seperator Engine oil filter Engine water filter Fuel oil filter Gearbox filter Hydraulic filter Pressure loss air filter fittings More...
    • Heat exchange system Heat exchange system
      Condenser/Evaporator Engine oil cooler Intercooler Radiator More...
    • Hose Hose
      Air conditioner hose/CO2 hose/Flat hose Cooling water hose GB16897 Brake hose High pressure hose/Steel pipe High pressure oil rail/Sensor Intake manifold PVT Testing machine Turbo charging hose More...
    • Measuring equipment Measuring equipment
      Measuring equipment More...
    • NEV NEV
      Air conditioner compressor Cooling water pump Electric water pump PTC Heater SAE J2044 Quick connector TL electric vehicle function Vehicle mounted hydrogen storage cylinder More...
    • Shipbuilding heavy industry/Nuclear electric power/Ocean engineering Shipbuilding heavy industry/Nuclear electric power/Ocean engineering
      Nuclear electric power test stand Ocean engineering test stand Shipbuilding heavy industry test stand More...
    • Valve Valve
      Automotive check valve Automotive electronic water valve Automotive hydrogen valve Control valve Electromagnetic valve Expansion valve Gas cylinder / Hydrogen cylinder More...
  • Instrument Agent
    • yqfl111 yqfl111
      yqfl2222 More...
  • Test services
    • Automotive parts Automotive parts
      Automobile chassis/Front and rear axle gas circuit Automotive conveyor belt Child seat Fuel tank Safety belt More...
    • Fire control/Drip irrigation/Container Fire control/Drip irrigation/Container
      Drip irrigation tape Emergency lamp Fire extinguisher Fire hose Fire hydrant Fire sprinkler Fire test equipment performance Packaging container Valve More...
    • Household electrical appliance/Water purifier/Water tank Household electrical appliance/Water purifier/Water tank
      Air conditioner dual purpose Liquid storage tank/Gas-liquid separator Water pump Water purifier Water tank More...
    • Intelligent toilet/Water efficiency Intelligent toilet/Water efficiency
      Toilet pan Water efficiency More...
    • Rail Transit Rail Transit
      Full vehicle High pressure oil hose/Brake hose Multiple unit trains door Railway seat Sound barrier Water cooled substrate/Radiator More...
  • Cooperative agencies
  • Recruit
  • Contact Us
Automotive parts Fire control/Drip irrigation/Container Household electrical appliance/Water purifier/Water tank Intelligent toilet/Water efficiency Rail Transit
-- ThirdLaboratory -- Water efficiency

Water purifier water purification performance test bench

Sort: Water efficiency Download

< >
Detail

1. According to the standard:

GB4144-2010 Household and similar reverse osmosis drinking water treatment purifier 5.4 Performance

GB34914-2017 Minimum allowable value of water efficiency and water efficiency grades for reverse osmosis drinking water treatment purifiers

GBT 30307-2013 Household and similar drinking water treatment equipment

2. Specification and model: JS-XL

3. Test items:

The system can test the performance of various household water purifiers and small water purifiers, water purifiers: Terminal water output, total water purification, water purification flow, desalination rate, recovery rate, etc.

4. Technical parameters:

System pressure: 0-0.25MPa, pressure accuracy: 0.01MPa

Pressure sensor range: 0-0.5Mpa, accuracy: 0.5%, actual test measurement: 0.12MPa

System drainage flow, system water supply flow: 0-2000l/h

Test switching time: <0.5s, timing accuracy: <0.1s

System temperature: 25±1°C

Temperature sensor accuracy: 0.5%, display accuracy: 0.1°C

Weighing measurement range: 0-5kg, accuracy: 0.1g

Water discharge specification of test piece: 0-100 L/h

The water supply branch of the test piece can be expanded: 1-20 stations, equipped with 1 set of testing device

Working conditions: Temperature 20°C-30°C, humidity 45~75%, good ventilation

Touch screen control, automatic data acquisition, automatic test control

Pressure regulation function: The system water supply pressure is adjustable, and the frequency conversion is manually adjusted according to the set value. Adjust the water pump speed to make the pump output pressure 0-0.25mpa, which can be used for constant pressure test under different working conditions.

Temperature control function: Test tank automatic temperature control 25±1°C

Automatic water supply switching function: The system uses the liquid storage tank to install the electric valve to switch the water supply, when one of the tank A reaches the lower level, the other tank B outlet valve is automatically opened, close the outlet solenoid valve of the storage tank, open the inlet valve of the tank A at the same time, the tank A starts to enter water, close the water inlet when the liquid level of tank A reaches the upper level. The storage tank B is also carried out in this order, and the two storage tanks of the AB are alternately so that the solution is continuously supplied to the water purifier by the feed water pump.


  • 走进紫微
  • 新闻中心
  • 产品中心
  • 应用案例
  • 行业应用产品
  • 合作机构
  • 招贤纳士
  • 联系我们
  • 公司介绍
  • 荣誉资质
  • 企业文化
  • 发展历程
  • 展会信息
  • 公司新闻
  • 行业资讯
  • Aeronautics & Astronautics/Military industry
  • Filter
  • Heat exchange system
  • Hose
  • Measuring equipment
  • NEV
  • Shipbuilding heavy industry/Nuclear electric power/Ocean engineering
  • Valve
  • Automotive parts
  • Fire control/Drip irrigation/Container
  • Household electrical appliance/Water purifier/Water tank
  • Intelligent toilet/Water efficiency
  • Rail Transit
  • 合作机构
  • 服务品牌
  • 招贤纳士
  • 联系方式 客户留言
Name
Water purifier water purification performance test bench
Sort
Water efficiency
Download
Download
Detail

1. According to the standard:

GB4144-2010 Household and similar reverse osmosis drinking water treatment purifier 5.4 Performance

GB34914-2017 Minimum allowable value of water efficiency and water efficiency grades for reverse osmosis drinking water treatment purifiers

GBT 30307-2013 Household and similar drinking water treatment equipment

2. Specification and model: JS-XL

3. Test items:

The system can test the performance of various household water purifiers and small water purifiers, water purifiers: Terminal water output, total water purification, water purification flow, desalination rate, recovery rate, etc.

4. Technical parameters:

System pressure: 0-0.25MPa, pressure accuracy: 0.01MPa

Pressure sensor range: 0-0.5Mpa, accuracy: 0.5%, actual test measurement: 0.12MPa

System drainage flow, system water supply flow: 0-2000l/h

Test switching time: <0.5s, timing accuracy: <0.1s

System temperature: 25±1°C

Temperature sensor accuracy: 0.5%, display accuracy: 0.1°C

Weighing measurement range: 0-5kg, accuracy: 0.1g

Water discharge specification of test piece: 0-100 L/h

The water supply branch of the test piece can be expanded: 1-20 stations, equipped with 1 set of testing device

Working conditions: Temperature 20°C-30°C, humidity 45~75%, good ventilation

Touch screen control, automatic data acquisition, automatic test control

Pressure regulation function: The system water supply pressure is adjustable, and the frequency conversion is manually adjusted according to the set value. Adjust the water pump speed to make the pump output pressure 0-0.25mpa, which can be used for constant pressure test under different working conditions.

Temperature control function: Test tank automatic temperature control 25±1°C

Automatic water supply switching function: The system uses the liquid storage tank to install the electric valve to switch the water supply, when one of the tank A reaches the lower level, the other tank B outlet valve is automatically opened, close the outlet solenoid valve of the storage tank, open the inlet valve of the tank A at the same time, the tank A starts to enter water, close the water inlet when the liquid level of tank A reaches the upper level. The storage tank B is also carried out in this order, and the two storage tanks of the AB are alternately so that the solution is continuously supplied to the water purifier by the feed water pump.


Video

Walk Into ZiWei
Company Introduction
Product Center
Aeronautics & Astronautics/Military industry
Filter
Heat exchange system
Hose
Measuring equipment
NEV
Shipbuilding heavy industry/Nuclear electric power/Ocean engineering
Valve
News Center
Company News
Industry News

National Service Telephone

024-25634391

Shenyang Ziweiheng Detection Equipment Co., Ltd. Copyright Liao ICP No. 05004390-1 All Rights Reserved.

Sale QQ

Back to Top